• Lead Acid Gel Battery 12V 24ah 33ah 38ah 40ah 65ah 100ah 200ah Inverter Gel Battery
  • Lead Acid Gel Battery 12V 24ah 33ah 38ah 40ah 65ah 100ah 200ah Inverter Gel Battery
  • Lead Acid Gel Battery 12V 24ah 33ah 38ah 40ah 65ah 100ah 200ah Inverter Gel Battery
  • Lead Acid Gel Battery 12V 24ah 33ah 38ah 40ah 65ah 100ah 200ah Inverter Gel Battery
  • Lead Acid Gel Battery 12V 24ah 33ah 38ah 40ah 65ah 100ah 200ah Inverter Gel Battery
  • Lead Acid Gel Battery 12V 24ah 33ah 38ah 40ah 65ah 100ah 200ah Inverter Gel Battery

Lead Acid Gel Battery 12V 24ah 33ah 38ah 40ah 65ah 100ah 200ah Inverter Gel Battery

Type: Lead-Acid Batteries
Usage: UPS, Electric Power, Lighting
Nominal Voltage: 12V
Discharge Rate: Low Discharge Rate
Shape: Square Battery
Electrolyte: Acid
Diamond Member Since 2021

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory

Basic Info.

Model NO.
FBR12-40
Installation
Fixed
Rechargeable
Chargeable
Color
Gray/Black/Customized
Certificate
CE, ISO, Ts16949, SGS, RoHS
Application
Inverter, Solar&Wind, EPS, Electric Vehicle
Transport Package
Carton
Specification
54*54*64cm
Trademark
FOBERRIA
Origin
Made in China
HS Code
8507200000
Production Capacity
10000PCS/Day

Product Description

>Main Features
1.Using oxygen recombination technology: maintenance-free
2.PbCaSn alloy for plate grids: less gassing, less self-discharging
3.High quality AGM separator: extend cycle life and prevent micro short circuit
4.ABS material: increase the strength of battery container. (Flame-retardant ABS is optional);
5.High purity raw material: ensure low self discharge rate
6.Silver-coated copper terminals (T1, T2 terminal), brass insert terminals and lead terminals improve the electric conductivity

>Specification
Battery Model No. FBR12V40Ah
Nominal Voltage 12V
Capacity
(25ºC)
20HR(5.25V) 40Ah
10HR(5.25V) 35Ah
1HR(4.80V) 24.5Ah
Dimension Length 197±2mm
Width 165±2mm
Height 175±2mm
Total height 175±2mm
Approx. Weight 12.5kg±4%
Terminal type F14
Internal resistance
(Fully charged,25ºC)
Approx 8.5mΩ
Capacity affected by
temperature(20HR)
40ºC 102%
25ºC 100%
0ºC 85%
-15ºC 65%
Self-discharge
(25ºC)
3month Remaining Capacity:91%
6month Remaining Capacity:82%
12month Remaining Capacity:65%
Nominal operating temperature 25ºC±3ºC(77ºF±5ºF)
Operating
temperature range
Discharge -15ºC-50ºC(5ºF-122ºF)
Charge -10ºC-50ºC(14ºF-122ºF)
Storage -20ºC-50ºC(-4ºF-122ºF)
Float charging voltage
(25ºC)
13.5 to 13.8V
Temperature compensation:-18mV/ºC
Cyclic charging voltage
(25ºC)
14.5 to 15V
Temperature compensation:-30mV/ºC
Max charging current 12A
Max discharging current 400A(5sec.)
Designed floating life(20ºC) 10years
 
>Applications 
1.Solar and wind energy storage system
2.EPS and UPS battery backup
3.Signal system , emergency lighting system , security system
4.Telecommunication Equipment
5.Power source for portable devices or tools
Lead Acid Gel Battery 12V 24ah 33ah 38ah 40ah 65ah 100ah 200ah Inverter Gel Battery
>Structure and composition
Component Pos. plate Neg. plate Container Cover Separator Electrolyte Safety valve Terminal
Raw material Lead dioxide Lead ABS ABS AGM Sulfuric acid Rubber Copper
Lead Acid Gel Battery 12V 24ah 33ah 38ah 40ah 65ah 100ah 200ah Inverter Gel Battery
>Constant Current Discharge Characteristics(A,25ºC)
F.V/Time 10min 15min 30min 60min 2h 3h 4h 5h 8h 10h 20h
9.6V 87.2 67.2 40.2 24.7 14.6 10.4 8.40 7.18 4.94 4.07 2.16
9.9V 84.6 65.6 39.4 24.3 14.5 10.3 8.36 7.14 4.91 4.06 2.15
10.2V 81.1 63.2 38.2 23.7 14.4 10.3 8.30 7.09 4.87 4.05 2.13
10.5V 77.6 61.0 37.3 23.2 14.2 10.2 8.24 7.04 4.84 4.03 2.13
10.8V 73.2 57.8 35.9 22.5 13.8 9.89 7.99 6.83 4.69 4.00 2.12

>Constant Power Discharge Characteristics(Watt,25ºC)
F.V/Time 10min 15min 30min 60min 2h 3h 4h 5h 8h 10h 20h
9.60V 942 738 451 282 169 122 98.8 84.9 58.6 48.6 25.9
9.90V 914 720 442 278 168 122 98.3 84.4 58.3 48.5 25.8
10.2V 876 694 428 271 167 121 97.6 83.8 57.9 48.4 25.8
10.5V 838 670 418 265 164 120 96.9 83.2 57.5 48.1 25.6
10.8V 791 635 403 257 160 116 94.0 80.7 55.8 47.8 25.4

Lead Acid Gel Battery 12V 24ah 33ah 38ah 40ah 65ah 100ah 200ah Inverter Gel BatteryLead Acid Gel Battery 12V 24ah 33ah 38ah 40ah 65ah 100ah 200ah Inverter Gel Battery
Lead Acid Gel Battery 12V 24ah 33ah 38ah 40ah 65ah 100ah 200ah Inverter Gel Battery
Lead Acid Gel Battery 12V 24ah 33ah 38ah 40ah 65ah 100ah 200ah Inverter Gel Battery
Lead Acid Gel Battery 12V 24ah 33ah 38ah 40ah 65ah 100ah 200ah Inverter Gel Battery
 
Lead Acid Gel Battery 12V 24ah 33ah 38ah 40ah 65ah 100ah 200ah Inverter Gel Battery
Lead Acid Gel Battery 12V 24ah 33ah 38ah 40ah 65ah 100ah 200ah Inverter Gel Battery
Lead Acid Gel Battery 12V 24ah 33ah 38ah 40ah 65ah 100ah 200ah Inverter Gel Battery

Q1: How to choose the right battery?
A1: Tell us your demand, then our sales will recommend a suitable battery for you. 
 
Q2. Do you have any MOQ limit?
A2: Yes, we have MOQ for mass production, it depends on the different model numbers. 50-500pcs sample order is available. for sample checking is available.
 
Q3. Is it OK to print my logo on the product?
A3: Yes. Please inform us formally before our production and confirm the design firstly based on our sample.
 
Q4: How to solve the technical problem?
A4: 24 hours after-service consultancy just for you and to make your problem to solve easily.
 
Q5:. What certificate your company have?
A5: ISO 9001, ISO 14001, OHSAS 18001, CE, UL, IEC 61427 test report, Patent for gel technology and other Chinese honor.
 
Q6.What is your warranty time for VRLA battery ?
A6: It depends on battery capacity, depth of discharge, and battery usage. Please kindly contact us for accurate information based on detailed requirements.
 
Q7. Why battery has different capacity at different hour rate?
A7: The capacity of a battery, in Ahs, is a dynamic number that is dependent on the discharge current. For example, a battery that is discharged at 10A will give you more capacity than a battery that is discharged at 100A. With the 20-hr rate, the battery is able to deliver more Ahs than with the 2-hr rate because the 20-hr rate uses a lower discharge current than the 2-hr rate.

Q8. Are you a battery manufacturer, and do you produce the plate by yourself ?
A8: Yes, we are a professional battery manufacture in Fujian Province, China. And we produce plates by ourselves.
 
Q9. How to proceed with an order?
A9. Firstly let us know your requirements or application. Secondly, We quote according to your requirements or our suggestions.
Thirdly customer confirms the samples and places a deposit for formal order.
Fourthly We arrange the production.

Q10: How about the delivery time?
A10: About 7 days for stock products, around 20 days for half container products, 30 days for 20ft full container products.


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now