Factory 12V 55ah~250ah Gel Battery VRLA Solar Battery Maintenance Free for Solar Inverter System

Product Details
Customization: Available
Type: Lead-Acid Batteries
Usage: UPS, Electric Power, Lighting
Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Fast Delivery
The supplier can deliver the goods within 30 days
to see all verified strength labels (9)
  • Factory 12V 55ah~250ah Gel Battery VRLA Solar Battery Maintenance Free for Solar Inverter System
  • Factory 12V 55ah~250ah Gel Battery VRLA Solar Battery Maintenance Free for Solar Inverter System
  • Factory 12V 55ah~250ah Gel Battery VRLA Solar Battery Maintenance Free for Solar Inverter System
  • Factory 12V 55ah~250ah Gel Battery VRLA Solar Battery Maintenance Free for Solar Inverter System
  • Factory 12V 55ah~250ah Gel Battery VRLA Solar Battery Maintenance Free for Solar Inverter System
  • Factory 12V 55ah~250ah Gel Battery VRLA Solar Battery Maintenance Free for Solar Inverter System
Find Similar Products

Basic Info.

Model NO.
12v65
Discharge Rate
Low Discharge Rate
Shape
Square Battery
Electrolyte
Acid
Installation
Fixed
Rechargeable
Chargeable
Application
UPS
Color
Gray
Warranty
3years
Transport Package
Carton
Specification
54*54*64cm
Trademark
FOBERRIA
Origin
Made in China
HS Code
8507200000

Product Description

>About VRLA battery (AGM & GEL)

What is VRLA battery?

VRLA(Valve Regulated Lead Acid) battery is sealed lead -acid battery. liclides GEL type and AGM type, 
both have the following characteristics:

*is sealed using special pressure valves and should never be opened.

*is completely maintenance-free,needn't topping in service life.

*all of its electrolyte are immobilized (absorbed in AGM or fixed in Gel structure).

*uses recombination reaction to prevent the escape of hydrogen and oxygen gases which normally lost in flooded lead- acid battery.

*is non-spillable, and therefore can be operated in virtually any position(except upside down). 


What is GEL battery?

Besides the characteristics of VRL A, GEL battery has :

*using thixotropic gelled electrolyte, it is in a solid state between the plates and separators.

*not like traditional  AGM electrolyte "starve" design, GEL battery has more 15~25%electrolyte volume than AGM type.

*different type of separator, such as PE, PVC etc .


Differences between GEL batteries and absorbed glass mat(AGM) batteries?

*Both are sealed recombinant batteries. Both are sealed valve-regulated lead-acid (VRLA). 
AGM batteries and GEL batteries are both considered "acid-starved" and the electrolyte does not flow like  a normal liquid.


*The gel electrolyte has the consistency and appearance of petroleum jelly. Like gelled electrolyte batteries, AGM batteries are also 
considered non-spillable - all of the liquid electrolyte is trapped in the sponge-like matted glass fiber separator material.

*Due to the physical properties of the gelled electrolyte, gel battery has higher internal resistance. Thus AGM batteries has excellent  performance for high current/power discharge and GEL excels in high/lower temperature stability and lower current/power discharge 
applications.

*AGM batteries has higher specific energy density than GEL batteries. But GEL batteries has longer service life.


What is the difference between VRLA batteries and traditional wet/flooded batteries? 

*Wet batteries do not have special pressurized sealing vents, as they do not work on the recombination principle(gases escaped 
inside the battery during charging).

*It contains liquid electrolyte that can spill/flow and cause corrosion if tipped or punctured. Therefore, they are not air transportable 
without special containers.

*It can only be installed "upright" and "acid protection" must be maintained at the same time.

*As the wet batteries will lose gases during charging ,it is need maintenance(topping) periodically. 

*As the electrolyte can flow , "stratification" will occur and need more overcharge to mix.

 
>Applications 

1.Solar and wind energy storage system

2.EPS and UPS battery backup

3.Signal system , emergency lighting system , security system

4.Telecommunication Equipment

5.Power source for portable devices or tools

>Main Features
1.Using oxygen recombination technology: maintenance-free
2.PbCaSn alloy for plate grids: less gassing, less self-discharging
3.High quality AGM separator: extend cycle life and prevent micro short circuit
4.ABS material: increase the strength of battery container. (Flame-retardant ABS is optional);
5.High purity raw material: ensure low self discharge rate
6.Silver-coated copper terminals (T1, T2 terminal), brass insert terminals and lead terminals improve the electric conductivity


>Specification
Battery Model No. FBR12V65Ah
Nominal Voltage 12V
Capacity
(25ºC)
10HR(10.8V)
65Ah
5HR(10.5V)
57Ah
1HR(9.60V)
40Ah
Dimension Length 350±2mm
Width 167±2mm
Height 175±2mm
Total height 175±2mm
Approx. Weight 20kg±4%
Terminal type F14
Internal resistance
(Fully charged,25ºC)
Approx 6mΩ
Capacity affected by
temperature(20HR)
40ºC 102%
25ºC 100%
0ºC 85%
-15ºC 65%
Self-discharge
(25ºC)
3month Remaining Capacity:91%
6month Remaining Capacity:82%
12month Remaining Capacity:65%
Nominal operating temperature 25ºC±3ºC(77ºF±5ºF)
Operating
temperature range
Discharge -15ºC-50ºC(5ºF-122ºF)
Charge -10ºC-50ºC(14ºF-122ºF)
Storage -20ºC-50ºC(-4ºF-122ºF)
Float charging voltage
(25ºC)
13.5 to 13.8V
Temperature compensation:-18mV/ºC
Cyclic charging voltage
(25ºC)
14.5 to 15V
Temperature compensation:-30mV/ºC
Max charging current 19.5A
Max discharging current 650A(5sec.)
Designed floating life(20ºC) 10years

>Structure and composition
Component Pos. plate Neg. plate Container Cover Separator Electrolyte Safety valve Terminal
Raw material Lead dioxide Lead ABS ABS AGM Sulfuric acid Rubber Copper
Factory 12V 55ah~250ah Gel Battery VRLA Solar Battery Maintenance Free for Solar Inverter SystemFactory 12V 55ah~250ah Gel Battery VRLA Solar Battery Maintenance Free for Solar Inverter SystemFactory 12V 55ah~250ah Gel Battery VRLA Solar Battery Maintenance Free for Solar Inverter System
Factory 12V 55ah~250ah Gel Battery VRLA Solar Battery Maintenance Free for Solar Inverter SystemFactory 12V 55ah~250ah Gel Battery VRLA Solar Battery Maintenance Free for Solar Inverter SystemFactory 12V 55ah~250ah Gel Battery VRLA Solar Battery Maintenance Free for Solar Inverter System
 
Factory 12V 55ah~250ah Gel Battery VRLA Solar Battery Maintenance Free for Solar Inverter System
Factory 12V 55ah~250ah Gel Battery VRLA Solar Battery Maintenance Free for Solar Inverter System
 
Factory 12V 55ah~250ah Gel Battery VRLA Solar Battery Maintenance Free for Solar Inverter System
Factory 12V 55ah~250ah Gel Battery VRLA Solar Battery Maintenance Free for Solar Inverter System

Q1: How to choose the right battery?
A1: Tell us your demand, then our sales will recommend a suitable battery for you. 
 
Q2. Do you have any MOQ limit?
A2: Yes, we have MOQ for mass production, it depends on the different model numbers. 50-500pcs sample order is available. for sample checking is available.
 
Q3. Is it OK to print my logo on the product?
A3: Yes. Please inform us formally before our production and confirm the design firstly based on our sample.
 
Q4: How to solve the technical problem?
A4: 24 hours after-service consultancy just for you and to make your problem to solve easily.
 
Q5:. What certificate your company have?
A5: ISO 9001, ISO 14001, OHSAS 18001, CE,  IEC 61427 test report, Patent for gel technology and other Chinese honor.
 
Q6.What is your warranty time for VRLA battery ?
A6: It depends on battery capacity, depth of discharge, and battery usage. Please kindly contact us for accurate information based on detailed requirements.
 
Q7. Why battery has different capacity at different hour rate?
A7: The capacity of a battery, in Ahs, is a dynamic number that is dependent on the discharge current. For example, a battery that is discharged at 10A will give you more capacity than a battery that is discharged at 100A. With the 20-hr rate, the battery is able to deliver more Ahs than with the 2-hr rate because the 20-hr rate uses a lower discharge current than the 2-hr rate.

Q8. Are you a battery manufacturer, and do you produce the plate by yourself ?
A8: Yes, we are a professional battery manufacture in Fujian Province, China. And we produce plates by ourselves.
 
Q9. How to proceed with an order?
A9. Firstly let us know your requirements or application. Secondly, We quote according to your requirements or our suggestions.
Thirdly customer confirms the samples and places a deposit for formal order.
Fourthly We arrange the production.

Q10: How about the delivery time?
A10: About 7 days for stock products, around 20 days for half container products, 30 days for 20ft full container products.



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier